Update of Design Code

To update the code check requirements based on more recent Recommended Practice. i.e.: 1. Fatigue option 'ERD' is based on DNV RP-C203 (2014). While this revision had long been superseded and not available from DNV website, we need to perform/veri...
about 1 year ago in  0 Needs review

SACS-PSI MODULE, Adjust the location of seismic force input on the pile foundation.

Considering the effects of seismic actions on soil properties, ISO 19901-2 and DNV-RP-0585 recommend that seismic forces be applied at one-third of the pile length. May I ask if the PSI module allows adjustment of the seismic force input location?...
5 months ago in  0 Needs review

Additional features for post processing _ SACS Python API

I am currently working with the new SACS API to automate the post-processing of analysis results and have noticed that several functions that could be very helpful are not yet available. These additional features could greatly enhance our efficien...
5 months ago in  1 Needs review

Improved Detailed Reports

Detailed reports could use more information and equations to make the calculations clearer and validation easier.
almost 3 years ago in  0 Needs review

Add a side window in Datagen with a list of links to different parts of input models

Dear Bentley, it would be awsome to have a sort of "tree menu" in a side window of datagen containing a structured list of links that allow to quickly navigate inside the input model. The list could be something like: - OPTIONS -GROUPS -MEMBERS -J...
over 1 year ago in  0 Needs review

Post View Database

Add the ability to tab through load case results one at a time. This was in the old postvue and was removed. Please put it back in the new view results.
over 1 year ago in  1 Needs review

Make results of deflection results for the SPAN members available in postview and sacsdb

Currently, the deflection/servicability check for the "SPAN" members are only available in saclst report. It would be good for the postview and the and sacsdb (sqlite database) to also include the results.
about 2 years ago in  0 Needs review

SACS error correction module

Press the error correction button to list all errors in a seperate window with error number, cause and possible soultions to each error code. help manual with all error codes to be included.
about 1 year ago in  0 Needs review

Automeshing of plated structure

Model a single plate using 3 or 4 points . Press the "Automesher button" to get the best possible FE mesh (either mesh or meshless technique) by default.
about 1 year ago in  0 Needs review

DNV Alternative SCF Formula

Dear Bentley I would like to propose to have DNV alternative SCF formula for the correction of Efthymiou SCF equation. Refer to DNV-RP-C203 (2021), Table B-1 shows alternative SCF equation for the Chord/Brace Crown location i.e. Eq 6b and 7b, see ...