Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

2 levels of super-element in SACS

Dear Bentley I would like to request an option to perform 2-levels super-element creation. For example, We import super-element from party 'A' to apply at joint #1. In our analysis, we also need to create super-element at joint #2 for party 'B' to...
over 1 year ago in  0 Needs review

Synchronized Update of Multiple Selected files from a Single Open File

This is for Bentley SACS. Latest being used and for Upcoming versions. The improvement ideas are : Live update of multiple selected files from SACS Precede GUI of a single open file (Such as, one In-place file edits must repeat in all pre-service ...
about 1 month ago in  0 Needs review

Create two fields to set Lb in the MEMBER card (one for bottom flange and one for top flange)

In the current input file structure in SACS there is an option to set the buckling length of the bottom flange of wide flange beams separately in the GRUP card. This means that for every physical member separate GRUP cards need to be created to se...
over 3 years ago in  1 Needs review

Perform fatigue analysis considering different S-N curves for chord and brace

Consider the possibility to assign different S-N curve for brace and chord in a tubular connection as suggested by DNV-RP-C203 (F.10.2)
5 months ago in  0 Needs review

Fatigue Extract File - Data extraction

Currently, when performing a spectral fatigue analysis, the SACS software generates a Fatigue Extract file, which can be opened in Precede as a PostVue database for fatigue results. From there, detailed fatigue information such as Design Life, Str...
about 2 months ago in  0 Needs review

DNV Alternative SCF Formula

Dear Bentley I would like to propose to have DNV alternative SCF formula for the correction of Efthymiou SCF equation. Refer to DNV-RP-C203 (2021), Table B-1 shows alternative SCF equation for the Chord/Brace Crown location i.e. Eq 6b and 7b, see ...
over 2 years ago in  0 Needs review

Change TOW coordinate system back to what an engineer intuitive would expect

If one reads the definition in DataGen or in the 'input lines' in the Tow manual one expect that XYZ-TOW-coordinate system implies that roll is about X and pitch about Y of one's SACS-model-coordinate system and not that the Z-axis flips downward ...
over 1 year ago in  1 Needs review

Rainflow counting module

As we know that SACS already use rainflow counting method in the fatigue calculation of Time History Analysis "I request SACS to separate the rainflow counting out as a separate module which user can call to use with other module rather than only ...
about 2 years ago in  0 Needs review

Create SACS Database (SACSDB) from CSF file without performing code check

Dear Bentley, I would like to have option to create SACS Database (SACSDB) to play with SQLite from CSF file without performing code check. Currently, SACSDB will not generate for common analysis i.e. wave reponse, dynamic response. I will have op...
almost 2 years ago in  0 Needs review

SACS ROARK RING ANALYSIS

Dear Bentley, I request to update SACS ring utility programme based on latest Roark's Formulas for Stress and Strain book. Further, the following update is desired. The unit system of present Roarks program should be updated for MKS/SI system The ...
about 3 years ago in  0 Needs review