Pressure load applied ON PLATE is getting deleted while meshing

Including the latest version of the SACS release, the pressure loadings applied on plate (as a plate pressure) is getting deleted once the loaded plates are undergoing further meshing. It is evident that meshing of plate is a very important featur...
5 months ago in  0 Needs review

Drag And Mass Coefficients + wake encounter for members that are NOT nearly vertical (more than 15 degrees from vertical)

In the current version, SACS only calculates wake encounter for members that are almost vertical (within 15 degrees) if I enter WE or WD in CDM card. However , the option for NOT nearly vertical members (more than 15 degrees from vertical) is not ...
5 months ago in  0 Needs review

Datagen needs "Replace all IN SELECTION" feature

Currently, I can press Alt and do a column selection in Datagen but I can't replace the values in the selection only. Many text editors like Notepad++ or VScode have this option.
about 1 year ago in  0 Needs review

Make results of deflection results for the SPAN members available in postview and sacsdb

Currently, the deflection/servicability check for the "SPAN" members are only available in saclst report. It would be good for the postview and the and sacsdb (sqlite database) to also include the results.
about 1 year ago in  0 Needs review

Add the ability to see Weight Combination Summation in precede.

No description provided
11 months ago in  0 Needs review

SACS Collapse Advanced Log file to have time stamps.

This way you can see how long each iteration takes.
11 months ago in  0 Needs review

Collapse programs termination criteria - load factor continues to reduce (maximum capacity reached)

None of the below criteria reflects the main purpose of a collapse analysis - to get maximum capacity before or at collapse. 1. The load sequence has been completed. 2. The maximum deflection has been reached. 3. The maximum number of iterations ...
about 1 year ago in  0 Needs review

Export the values in graphics in collapse analysis.

When we develop a Collapse analysis graphically in postvue we can see the results and create graphics whit the results of the analysis, for example, I would like to extract the data of Load Factor against the Energy Absorbed when I make an Impact ...
over 1 year ago in  0 Already exists

Wind Coherence Function and Decay Factors

Refer to Section 3.4.3 of Dynamic Response Manual, only Davenport Coherence Function is available. Moreover, the decay factors are fixed at 12 and 8 for Cy and Cz. The suggestion is Allow user to change the Decay factors for Davenport Coherence Fu...
about 1 year ago in  0 Needs review

Changing contact email to log-in to the Bentley system

It is suggest that Bentley allows to change the email which is used for log-in to bentley systems and also can provide second email or backup email in case of the 1st email is not available anymore.