Please see the example of inconsistent LOAD / SHEAR / MOMENT diagrams offered by SACS for the test case discussed in incident CS0432943, with the relevant details and discussion. Basically, the LOAD values shown in the diagram are significantly different (about ten times lower) from the actual values, as well as the graphics representation of the same. It was clarified that the problem is actually limited to the graphic tool, not the content of the SACS files (OCI). However, the users need the graphic tools, take their correctness for granted and make design decisions accordingly. Either the graphics tool is correct and reliable or there is no point to have it. Please check the graphic tool and correct it as needed. Thanks