Modify datagen to accomodate commands similar to Bentley Staad

No headache of moving keywords to a particular column for it to execute i.e. column restrictions are removed for good!
about 1 year ago in  0 Needs review

Add equipment load

Add equipment in the form of a box with loads applied at the CoG of the box with user defined height above base. i.e. input Equipment details as : a) LXBXH b) CoG height above base c) Provide option to user to pick any no. of "n" random points on ...
about 1 year ago in  1 Needs review

Toggle button to Show/Hide skipped members

Helps users identify members considered for code checking by the software. The button can be provided for both precede and postvue
about 1 year ago in  1 Needs review

Add Standard Report Appendix button

This would Reduce time for reporting and provides users more time to concentrate on optimizing and bettering their designs. Standard Appendix for post processing should include: Appendix1 : Automatic printing of all saved views in wireframe, scale...
about 1 year ago in  0 Needs review

Temperature Variation Simulation option

My current Project requirement is to check member stresses due to temperature variation between winter season (-25 Deg C) to summer season (+40 Deg C). However, we cannot simulate this load in SACS. However, STAAD Pro can simulate the Stresses due...
about 2 years ago in  1 Needs review

Library sections - tidy up section names & single library

No description provided
about 2 years ago in  1 Needs review

Pressure load applied ON PLATE is getting deleted while meshing

Including the latest version of the SACS release, the pressure loadings applied on plate (as a plate pressure) is getting deleted once the loaded plates are undergoing further meshing. It is evident that meshing of plate is a very important featur...
about 1 year ago in  0 Needs review

Drag And Mass Coefficients + wake encounter for members that are NOT nearly vertical (more than 15 degrees from vertical)

In the current version, SACS only calculates wake encounter for members that are almost vertical (within 15 degrees) if I enter WE or WD in CDM card. However , the option for NOT nearly vertical members (more than 15 degrees from vertical) is not ...
about 1 year ago in  0 Needs review

In-Line Tubular Fatigue Life

Having the option to only look at results for inline tubular fatigue lives would be helpful.
over 1 year ago in  2 Needs review

Put the Time Log in the Collapse Advance output

the time log was always printed in the Standard Collapse. it is a good way to see how efficient the analyses are running.
over 1 year ago in  2 Needs review