SACS Collapse Advanced Log file to have time stamps.

This way you can see how long each iteration takes.
over 1 year ago in  0 Needs review

SACS input file size

Hi , Has it ever happened to anyone that theri SACS file size increased even though minor changes were done?
10 months ago in  0 Needs review

Modify datagen to accomodate commands similar to Bentley Staad

No headache of moving keywords to a particular column for it to execute i.e. column restrictions are removed for good!
10 months ago in  0 Needs review

Add equipment load

Add equipment in the form of a box with loads applied at the CoG of the box with user defined height above base. i.e. input Equipment details as : a) LXBXH b) CoG height above base c) Provide option to user to pick any no. of "n" random points on ...
10 months ago in  1 Needs review

Toggle button to Show/Hide skipped members

Helps users identify members considered for code checking by the software. The button can be provided for both precede and postvue
10 months ago in  1 Needs review

Add Standard Report Appendix button

This would Reduce time for reporting and provides users more time to concentrate on optimizing and bettering their designs. Standard Appendix for post processing should include: Appendix1 : Automatic printing of all saved views in wireframe, scale...
10 months ago in  0 Needs review

Collapse programs termination criteria - load factor continues to reduce (maximum capacity reached)

None of the below criteria reflects the main purpose of a collapse analysis - to get maximum capacity before or at collapse. 1. The load sequence has been completed. 2. The maximum deflection has been reached. 3. The maximum number of iterations ...
over 1 year ago in  0 Needs review

Wind Coherence Function and Decay Factors

Refer to Section 3.4.3 of Dynamic Response Manual, only Davenport Coherence Function is available. Moreover, the decay factors are fixed at 12 and 8 for Cy and Cz. The suggestion is Allow user to change the Decay factors for Davenport Coherence Fu...
over 1 year ago in  0 Needs review

Changing contact email to log-in to the Bentley system

It is suggest that Bentley allows to change the email which is used for log-in to bentley systems and also can provide second email or backup email in case of the 1st email is not available anymore.
over 1 year ago in  0 Needs review

Include footprint Group

Actually, in SACS we have the option to exclude group elements when we use the weight option "footprint weight" by the card EXCGRP (Footprint group exclusion), but sometimes the group list to include is shorter than the exclude list, it will be gr...